In the US for example the standard is 110V for voltage and 80psi for water. In Europe, voltage is 220V, is water pressure different there too?

    • NeptuneOrbit@lemmy.world
      link
      fedilink
      arrow-up
      26
      ·
      edit-2
      4 months ago

      Everyone else is focusing on whether the rest of the world uses metric and not that fact that water pressure at a given faucet or shower head will be governed by bernoullis equation which will take 99 things into account such as:

      The max height of the water reservoir

      The height of your faucet

      The design of the pipes leading from the reservoir to your faucet

      Air pressure

      The pumps in the system

      Etc

    • Thorny_Insight@lemm.ee
      link
      fedilink
      arrow-up
      5
      ·
      4 months ago

      And the location of the house/apartment. Houses higher up have lower water pressure and in apartment buildings the upper floors have lower pressure than bottom floors. 1bar of pressure lifts water 10 meters high. When constructing heating lines on a new building we might have the heating on on the first 3 floors despite the ends of the pipes leading to upper floors still being open and half of the building missing. The water wont spray out as long as we keep the pressure low enought that it doesn’t rise to where the pipes end.

  • Brkdncr@lemmy.world
    link
    fedilink
    arrow-up
    27
    ·
    4 months ago

    Water operates more like DC voltage so there isn’t really a need for a standard. You just need enough to get to your shower head.

    • ramble81@lemm.eeOP
      link
      fedilink
      arrow-up
      5
      ·
      4 months ago

      That’s an interesting analogy. But just like too much current can melt a wire, I would assume there’s some upper limits to keep it from bursting pipes and fittings?

          • Brkdncr@lemmy.world
            link
            fedilink
            arrow-up
            3
            ·
            4 months ago

            US. I’d be surprised if anywhere was allowing more than 80psi.

            20psi is really low so this value may have different variations. I’m on a well pump and before I replaced it I was getting down to 20psi. It barely dribbled out of the 2nd floor shower head. I now have the pump set to 60/40 with a 50psi restriction valve. This seems to be the sweet spot.

            I’m not in plumbing and won’t know how to look this stuff up.

  • neidu2@feddit.nl
    link
    fedilink
    arrow-up
    20
    ·
    edit-2
    4 months ago

    Noggie here. Code dictates a minimum of 2Bar (~30psi), but it’s usually between 3-6 bar.

    The pressure at my house was recently measured as I had some plumbing work done, and in my 2nd floor bathroom it clocked in at around 5 bar (75ish psi, I think)

  • Aux@lemmy.world
    link
    fedilink
    arrow-up
    12
    ·
    4 months ago

    Here in the UK the legal minimum is 1 bar per 10m of elevation. But usually the tap will have between 2 and 4 bars of pressure. Older buildings might only have 1 bar ofc. And by older I mean stuff that was built centuries ago and proper modern water supply is impossible to install.

  • abcd@feddit.de
    link
    fedilink
    arrow-up
    9
    ·
    4 months ago

    My house is operating at around 3,5-4 bar after the pressure regulator. Since I have no gauge I can‘t deliver the pressure of the supply. I guess it is around 6 bar. Small town in Germany.

    We also have mandatory check valves since a couple of years to prevent water from entering the supply from the buildings in case the pressure drops.

  • RightHandOfIkaros@lemmy.world
    link
    fedilink
    English
    arrow-up
    9
    arrow-down
    1
    ·
    edit-2
    4 months ago

    Not European, but I think they might not use PSI since that’s Pounds per Square Inch. I believe they use Pascals/ Bar.

    • ramble81@lemm.eeOP
      link
      fedilink
      arrow-up
      10
      arrow-down
      1
      ·
      4 months ago

      Doesn’t really matter the unit of measurement. Kinda like hp/ps or lb-ft/nm, there are equivalents. I’m more interested in the values, but you do have a valid point there.

      • Aux@lemmy.world
        link
        fedilink
        arrow-up
        5
        arrow-down
        1
        ·
        4 months ago

        Well, you’re asking about other countries and literally no one knows what PSI is :)

  • Spuddlesv2@lemmy.ca
    link
    fedilink
    arrow-up
    8
    ·
    4 months ago

    Australia uses kilopascals rather than PSI. Our standard is 500kPa which works out at around 72 PSI.

  • Zwiebel@feddit.org
    link
    fedilink
    English
    arrow-up
    6
    ·
    edit-2
    4 months ago

    The most common one is bar. 1 bar is roughly the atmospheric pressure.

    An older German unit was atü, 0 atü is atmosperic pressure

    Edit: sorry I misunderstood the question

  • NeoNachtwaechter@lemmy.world
    link
    fedilink
    arrow-up
    12
    arrow-down
    8
    ·
    4 months ago

    80psi

    different there too?

    Of course, because psi exists only inside Usa. The real world does not use body parts for measurement anymore ;-)

  • Macaroni_ninja@lemmy.world
    link
    fedilink
    arrow-up
    4
    ·
    4 months ago

    In europe they mostly use Bars as the unit of measurement.

    Mostly water pressure is around 1-2 bars as a minimum, but there are still places using different standards, for example the old style gravity-fed UK watersystems with sub 1 bar pressure, but those are not very common anymore.

    Most domestic sanitary products in the EU are designed to be used on 1-5 bar pressure.

    I read somewhere the domestic water pressure to be between 4-6 bar, however not sure how realistic it is accross the whole EU and also what you got at the mains and what you got when opening the faucet is two different numbers.

    • AmidFuror@fedia.io
      link
      fedilink
      arrow-up
      2
      ·
      4 months ago

      A bar is 100,000 Pa or 100.000 Pa. Why not use KPa? Why set a separate unit to be 1E+05?

      • Contravariant@lemmy.world
        link
        fedilink
        arrow-up
        2
        ·
        4 months ago

        Because 1 bar is almost atmospheric pressure. Oddly enough I’ve never seen anyone use kPa, weather forecasts often use hPa (instead of mbar) to report atmospheric pressure.

      • Thorny_Insight@lemm.ee
        link
        fedilink
        arrow-up
        2
        ·
        4 months ago

        1 bar is enought to lift water 10 meters up. The pressure gauges reads zero at atmospheric pressure.

      • Macaroni_ninja@lemmy.world
        link
        fedilink
        arrow-up
        1
        ·
        edit-2
        4 months ago

        The gravity systems in this case are not pressurized. They just have a water tank in the loft/airing cupboard and the hight of the tank determines the pressure. 0.1 bar for every 1 meter height. You open the faucet and gravity pushes out the water.

        Its a nightmare, I used to live in UK and these systems are barely enough for anything really.

      • Zwiebel@feddit.org
        link
        fedilink
        English
        arrow-up
        4
        arrow-down
        2
        ·
        4 months ago

        It doesn’t matter one bit. The actual voltage from the wall varies, and devices are build to operate under a fairly wide margin.

      • Kaboom@reddthat.com
        link
        fedilink
        arrow-up
        3
        arrow-down
        5
        ·
        4 months ago

        Hes just being pedantic. Reality is US houses get a +120v and a -120v supply. Combine them is how you get 240v.

        • ramble81@lemm.eeOP
          link
          fedilink
          arrow-up
          4
          arrow-down
          1
          ·
          4 months ago

          There’s lots of pedantry going on in this thread rather than attempting to understand the spirit of the question.

        • ElongatedMuskrat@lemm.ee
          link
          fedilink
          arrow-up
          2
          ·
          edit-2
          4 months ago

          sorry dude thats not right. first off houses recieve AC power which cycles between positive and negative at 60hz ~120v rms in north america. they achieve a potential difference in voltage by basically taking a phase of power, splitting it into two lines and then lagging one line by 90° usually with the use of capacitance from what i was taught back in the day(Good ol ELI the ICEman). this phase shift now gives you a potential difference between those two lines of 240v and 120v between phase and ground. need to use phasor algebra with AC power. when dealing with 3 phase power you still wouldnt just add 120v plus 120v when going phase to phase, you would multiply 120v by the square root of 3 which gives you 208v.